{"EGODeployment": [{"DEPLOYMENT_ID": 556, "DEPLOYMENT_START_DATE": 20210322, "SUMMARY_REPORT": "This campaign involves the deployment of one slocum glider in the English channel as part of the Combining Autonomous observations and \nModels for Predicting and Understanding Shelf Seas (CAMPUS) project. The glider was deployed in March 2021 from Research Vessel Plymouth Quest.", "BASE_STATION": "Base Station version 2.8", "EMAIL": "avab@pml.ac.uk", "ACTIVE": 1, "CAMPAIGNNAME": "CAMPUS", "PROJNAME": "CAMPUS", "PLATFORMMODEL": [{"MODEL_VERSION_ID": 117, "MODEL_ID": 358, "CATEGORY_TYPE": "platforms", "DDESC": "G2", "PLATFORM_MAKER": "Teledyne Webb Research", "UNIQUE_ID": "B7600001", "PLATFORM_TYPE": "slocum", "MODEL_NAME": "G2", "WMO_INST_TYPE": 830}], "PLATFORMINSTANCE": [{"PLAT_INSTANCE_VERSION_ID": 868, "PLAT_INSTANCE_ID": 408, "DATA_TYPE": "EGO glider time-series data", "GLIDER_SERIAL_NO": "unit_438", "PLATFORM_CODE": "Frazil", "GLIDER_OWNER": "NOCS", "WMO_PLATFORM_CODE": 6801542, "PLATFORM_FAMILY": "open ocean glider"}], "SENSORLIST": [{"SENSORMODEL": [{"MODEL_VERSION_ID": 236, "MODEL_ID": 450, "SENSOR_MODEL": "Slocum G1+G2 Glider Navigation data logger", "SENSOR_MAKER": "Teledyne Webb Research", "MODEL_NAME": "Slocum G1+G2 Glider Navigation data logger", "INSTRUMENT_TYPE": "data loggers"}], "SENSORINSTANCE": [{"SENSOR_INSTANCE_VERSION_ID": 1060, "SENSOR_INSTANCE_ID": 602, "SENSOR_SERIAL_NO": "unit_438", "SENSOR_NAME": "TOOL1183_unit_438"}], "PARAMETERLIST": [{"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/ALATGP01/", "PREFLABEL": "Latitude north relative to WGS84 by unspecified GPS system", "SDN_UOM_UM": "SDN:P06::DEGN", "VALID_MIN": -90, "VALID_MAX": 90, "FILLVALUE": -99, "SOURCENAME": "m_gps_lat"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/AHSFZZ01/", "PREFLABEL": "Height (spatial coordinate) relative to bed surface in the water body", "SDN_UOM_UM": "SDN:P06::ULAA", "VALID_MIN": 0, "VALID_MAX": 12000, "FILLVALUE": -1, "SOURCENAME": "m_altitude"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/ROLLFG01/", "PREFLABEL": "Orientation (roll angle) of measurement platform by triaxial fluxgate compass", "SDN_UOM_UM": "SDN:P06::UAAA", "VALID_MIN": -180, "VALID_MAX": 180, "FILLVALUE": -999, "SOURCENAME": "m_roll"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/LCEWZZ01/", "PREFLABEL": "Eastward velocity of water current in the water body", "SDN_UOM_UM": "SDN:P06::UVAA", "VALID_MIN": -500, "VALID_MAX": 500, "FILLVALUE": -9999, "SOURCENAME": "m_water_vx"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/ALATZZ01/", "PREFLABEL": "Latitude north", "SDN_UOM_UM": "SDN:P06::DEGN", "VALID_MIN": -90, "VALID_MAX": 90, "FILLVALUE": -99, "SOURCENAME": "m_lat"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/LCNSZZ01/", "PREFLABEL": "Northward velocity of water current in the water body", "SDN_UOM_UM": "SDN:P06::UVAA", "VALID_MIN": -500, "VALID_MAX": 500, "FILLVALUE": -9999, "SOURCENAME": "m_water_vy"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/ADEPZZ01/", "PREFLABEL": "Depth (spatial coordinate) relative to water surface in the water body", "SDN_UOM_UM": "SDN:P06::ULAA", "VALID_MIN": 0, "VALID_MAX": 9999, "FILLVALUE": -1, "SOURCENAME": "m_depth"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/ALONGP01/", "PREFLABEL": "Longitude east relative to WGS84 by unspecified GPS system", "SDN_UOM_UM": "SDN:P06::DEGE", "VALID_MIN": -180, "VALID_MAX": 180, "FILLVALUE": -999, "SOURCENAME": "m_gps_lon"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/ALONZZ01/", "PREFLABEL": "Longitude east", "SDN_UOM_UM": "SDN:P06::DEGE", "VALID_MIN": -180, "VALID_MAX": 180, "FILLVALUE": -999, "SOURCENAME": "m_lon"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/PTCHFG01/", "PREFLABEL": "Orientation (pitch) of measurement platform by triaxial fluxgate compass", "SDN_UOM_UM": "SDN:P06::UAAA", "VALID_MIN": -180, "VALID_MAX": 180, "FILLVALUE": -999, "SOURCENAME": "m_pitch"}]}, {"SENSORMODEL": [{"MODEL_VERSION_ID": 234, "MODEL_ID": 448, "SENSOR_MODEL": "Oxygen optode 4831", "SENSOR_MAKER": "Aanderaa", "MODEL_NAME": "Oxygen optode 4831"}], "SENSORINSTANCE": [{"SENSOR_INSTANCE_VERSION_ID": 1524, "SENSOR_INSTANCE_ID": 1068, "SENSOR_SERIAL_NO": 230, "SENSOR_NAME": "Aanderaa Oxygen optode 4831 230"}], "PARAMETERLIST": [{"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/OXYCOPVB/", "PREFLABEL": "Raw signal (voltage) of instrument output (blue light wavelength excitation) by optode", "SDN_UOM_UM": "SDN:P06::UUMV", "VALID_MIN": 0, "VALID_MAX": 9999, "FILLVALUE": -1, "SOURCENAME": "sci_oxy4_c1amp"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/OXYCPHAB/", "PREFLABEL": "Phase angle of blue light wavelength excitation {BPhase} by optode", "SDN_UOM_UM": "SDN:P06::UAAA", "VALID_MIN": 0, "VALID_MAX": 360, "FILLVALUE": -1, "SOURCENAME": "sci_oxy4_c1rph"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/OXYCPHAC/", "PREFLABEL": "Phase angle of D phase by optode", "SDN_UOM_UM": "SDN:P06::UAAA", "VALID_MIN": 0, "VALID_MAX": 360, "FILLVALUE": -1, "SOURCENAME": "sci_oxy4_calphase"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/DOXYAAOP/", "PREFLABEL": "Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by optode", "SDN_UOM_UM": "SDN:P06::UPOX", "VALID_MIN": 0, "VALID_MAX": 600, "FILLVALUE": -1, "SOURCENAME": "sci_oxy4_oxygen"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/OXYCPHTC/", "PREFLABEL": "Phase angle (temperature compensated) of D phase by optode", "SDN_UOM_UM": "SDN:P06::UAAA", "VALID_MIN": 0, "VALID_MAX": 360, "FILLVALUE": -1, "SOURCENAME": "sci_oxy4_tcphase"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/OXYCOPVR/", "PREFLABEL": "Raw signal (voltage) of instrument output (red light wavelength excitation) by optode", "SDN_UOM_UM": "SDN:P06::UUMV", "VALID_MIN": 0, "VALID_MAX": 9999, "FILLVALUE": -1, "SOURCENAME": "sci_oxy4_c2amp"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/OXYTAAOP/", "PREFLABEL": "Temperature of oxygen determination by optode", "SDN_UOM_UM": "SDN:P06::UPAA", "VALID_MIN": -2, "VALID_MAX": 50, "FILLVALUE": -9, "SOURCENAME": "sci_oxy4_temp"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/OXYSOP01/", "PREFLABEL": "Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by in-situ oxygen optode and computation from concentration", "SDN_UOM_UM": "SDN:P06::UPCT", "VALID_MIN": 0, "VALID_MAX": 180, "FILLVALUE": -1, "SOURCENAME": "sci_oxy4_saturation"}]}, {"SENSORMODEL": [{"MODEL_VERSION_ID": 259, "MODEL_ID": 622, "SENSOR_MODEL": "WETLabs ECO Puck Triplet FLBBCD-SLC scattering fluorescence sensor", "SENSOR_MAKER": "WET Labs", "MODEL_NAME": "WETLabs ECO Puck Triplet FLBBCD-SLC scattering fluorescence sensor", "INSTRUMENT_TYPE": "radiometers"}], "SENSORINSTANCE": [{"SENSOR_INSTANCE_VERSION_ID": 1095, "SENSOR_INSTANCE_ID": 638, "SENSOR_SERIAL_NO": 3289, "SENSOR_NAME": "WET Labs FLBBCD 3289"}], "PARAMETERLIST": [{"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/BB117NIR/", "PREFLABEL": "Attenuation due to backscatter (700 nm wavelength at 117 degree incidence) by the water body [particulate >unknown phase] by in-situ optical backscatter measurement", "SDN_UOM_UM": "SDN:P06::UUUU", "VALID_MIN": 0, "VALID_MAX": 9, "FILLVALUE": -9, "SOURCENAME": "sci_flbbcd_bb_units"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/CDOMZZ01/", "PREFLABEL": "Concentration of coloured dissolved organic matter {CDOM Gelbstoff} per unit volume of the water body [dissolved plus reactive particulate phase] by fluorometry", "SDN_UOM_UM": "SDN:P06::UPPB", "VALID_MIN": 0, "VALID_MAX": 1000, "FILLVALUE": -999, "SOURCENAME": "sci_flbbcd_cdom_units"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/CPHLPR01/", "PREFLABEL": "Concentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by in-situ chlorophyll fluorometer", "SDN_UOM_UM": "SDN:P06::UMMC", "VALID_MIN": 0, "VALID_MAX": 999, "FILLVALUE": -1, "SOURCENAME": "sci_flbbcd_chlor_units"}]}, {"SENSORMODEL": [{"MODEL_VERSION_ID": 242, "MODEL_ID": 485, "SENSOR_MODEL": "SBE Slocum Glider Payload (GPCTD) CTD", "SENSOR_MAKER": "Sea-Bird Scientific", "MODEL_NAME": "SBE Slocum Glider Payload (GPCTD) CTD", "INSTRUMENT_TYPE": "water temperature sensor"}], "SENSORINSTANCE": [{"SENSOR_INSTANCE_VERSION_ID": 1130, "SENSOR_INSTANCE_ID": 677, "SENSOR_SERIAL_NO": 9100, "SENSOR_NAME": "SBE Glider Payload CTD 9100"}], "PARAMETERLIST": [{"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/PRESPR01/", "PREFLABEL": "Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level", "SDN_UOM_UM": "SDN:P06::UPDB", "VALID_MIN": 0, "VALID_MAX": 15000, "FILLVALUE": -99, "SOURCENAME": "sci_water_pressure"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/CNDCST01/", "PREFLABEL": "Electrical conductivity of the water body by CTD", "SDN_UOM_UM": "SDN:P06::UECA", "VALID_MIN": 0, "VALID_MAX": 6.5, "FILLVALUE": -1, "SOURCENAME": "sci_water_cond"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/TEMPST01/", "PREFLABEL": "Temperature of the water body by CTD or STD", "SDN_UOM_UM": "SDN:P06::UPAA", "VALID_MIN": -3, "VALID_MAX": 35, "FILLVALUE": -9, "SOURCENAME": "sci_water_temp"}]}, {"SENSORMODEL": [{"MODEL_VERSION_ID": 247, "MODEL_ID": 524, "SENSOR_MODEL": "Photosynthetically Active Radiation sensor", "SENSOR_MAKER": "WET Labs", "MODEL_NAME": "Photosynthetically Active Radiation sensor", "INSTRUMENT_TYPE": "radiometers"}], "SENSORINSTANCE": [{"SENSOR_INSTANCE_VERSION_ID": 1175, "SENSOR_INSTANCE_ID": 722, "SENSOR_SERIAL_NO": 459, "SENSOR_NAME": "WET Labs PAR sensor 459"}], "PARAMETERLIST": [{"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/DWIRRXUD/", "PREFLABEL": "Downwelling vector irradiance as energy of electromagnetic radiation (PAR wavelengths) in the water body by cosine-collector radiometer", "SDN_UOM_UM": "SDN:P06::UMES", "VALID_MIN": 0, "VALID_MAX": 1000, "FILLVALUE": -1, "SOURCENAME": "sci_satpar_par"}, {"OBJECTTYPE": "parameter", "SDN_PARAMETER_URN": "http://vocab.nerc.ac.uk/collection/P01/current/DWIRRXZZ/", "PREFLABEL": "Raw signal (counts) of instrument output by cosine-collector downwelling PAR radiometer", "SDN_UOM_UM": "SDN:P06::UUUU", "VALID_MIN": 0, "VALID_MAX": 99999999, "FILLVALUE": -999, "SOURCENAME": "sci_satpar_raw_counts"}]}]}]}